- Computer Cables & Connectors[10]
- Floor Heating Systems & Parts[3]
- HVAC Systems & Parts[3]
- Connectors[10]
- Electrical Plugs & Sockets[32]
- AC/DC Adapters[8]
- Audio & Video Cables[47]
- Electrical Wires[1]
- Power Cables[1]
- Other Household Cleaning Tools & Accessories[1]
- Vacuum Cleaners[8]
- Air Conditioner Parts[35]
- Electric Heater Parts[19]
- Vacuum Cleaner Parts[16]
- AC Motor[1]
- Valves[22]
- Communication Cables[11]
- Fiber Optic Equipment[19]
Hot Sales Ozone Gas Monitor And Alarm
1)Electrochemical ozone sensor
2)Particular LCD display with three color backlights
3)).Buzzer alarm
4)Humidity measurement
Hot Sales Ozone Gas Monitor And Alarm
1, Feature:
1)Design for real time detecting and monitoring ambiance ozone level and temperature
2)Electrochemical ozone sensor with high sensitivity
3)Particular LCD display with three color backlights (Green/Yellow/Red)
4)Maximum ozone measuring range:0~5ppm (0~9.81mg/m3) Also reset the measurement range by end user
5)2xOn/Off dry contact outputs for two stages alarm device, or control a ozone generator or a ventilator
6)Buzzer alarm and 3-color backlight LCD indication
7)Provide 1X analog output (0,2~10VDC/4~20mA)(can be used as transmitter)
8)Modbus RS485 communication interface, 15 KV antistatic protection, individual IP address
9)Provide two easy ways for calibration and setup alarm points via an infrared remote controller or via the RS485 interface.
10)Temperature measurement and display
11)Humidity measurement and display optional
12)Multiple application, wall mounting type and desktop type
13)Great performance with high quality and low price
2, Description:
Gas Detected | Ozone |
Sensing Element | Electrochemical gas sensor |
Sensor lifetime | >2 years, removable |
Temperature Sensor | NTC 5K |
Humidity Sensor | HS series capacitive sensor |
Power Supply | 24VAC/VDC (power adaptor selectable) |
Power Consumption | 2.8W |
Response Time | <50s @T90 |
Signal Update | 1s |
Warm up Time | <60 seconds |
Ozone Measuring Range | 0~5000ppb (0-5ppm)( 0~9.81mg/m3) |
Display Resolution | 1ppb (0.001ppm) (0.01mg/ m3) |
Accuracy | +-0.01ppm + 10% reading |
Nonlinear | <1%FS |
Repeatability | <0.5% |
Zero Drift | <1% |
Alarm | Buzzer and Yellow or Red backlight switch |
Display | Green-normally, yellow – first stage alarm, red- second stage alarm. Ozone alarm points can be preset. |
Temperature/humidity Measuring Range | -20°C~50°C (-4°F~122°F)/5~99%RH |
Analog Output | 0,2~10VDC or 4~20mA linearized output selectable |
Analog Output Resolution | 16Bit |
Relay dry contact Output | Two dry-contact outputs Max, switching current 3A (220VAC/30VDC), resistance Load |
Communication Interface | RS-485, 9600,14400,19200(default), 28800,38400 bps selectable, 15KV antistatic protection |
Working Condition | -20°C~45°C (-4°F~113°F)/ 0~ 95% RH |
Storage Conditions | -40°C~70°C (-40°F~158°F)/ 0~ 95% RH |
Net Weight | 190g |
Dimensions | 130mm(H)×85mm(W)×36.5mm(D) |
3, Picture: